Skip to main content

Selection guide

  • Acoustic comfort
  • Active fire protection

The advantages of the system

  • Aesthetics: panels on concealed structure with staggered edge joint to absorb alignment differences with the wall for a perfectly straight finish
  • Opening: demountable from below, ideal for crowded plenums
  • Plenum ventilation: suitable for hospital environments
  • Acoustics: high correction, absorption coefficient αw up to 1 (NRC = 1)

Description

  • Self-supporting ceiling made up of expanded metal panels hung on a concealed edge profile forming an open gap joint between the panel ends and the wall
  • Self-supporting steel panels with jointed edges
  • The panels are equipped with notches at their ends for suspension on the structure
  • The edge profile consists of a fixing range to be attached to the wall and a hanging profile to be offset and fixed under the wing of the range according to the length of the panel between notches. It allows the open joint formed to absorb alignment deviations with the wall
  • Acoustic enhancements available as an option

Bulk cut

A gap A is required between the panel and the wall. Dimensions in mm.

Appearance

  • Expanded mesh

    Dimensions

    • Mesh: Geometry WL x WD - LG x Th
    • Panel: width in the WL direction of the mesh, length in the WD direction

    Installation

    • The direction in which light enters through the mesh depends on its installation direction, visually identifiable by its tilt.
    • Depending on the desired visual effect, panels can be installed in the same direction or every other one inverted.

    *Aluminum option available, please contact us.

    KD100 <br>Q6x4.5-1.2x1
    KD100 Q6x4.5-1.2x1
    Geometry: Square (Q)
    Long Diagonal (LD): 6 mm
    Short Diagonal (SD): 4.5 mm
    Metal Strip Width (W): 1.2 mm
    Metal Thickness (T): 1 mm
    Total Thickness (TT): ≈ 1.5 mm
    Steel*: 4.2 kg/m²
    Front Open Area / max: ≈ 36% / 40%
    KD100 <br>Q6x4.5-1.2x1
    KD100
    Q6x4.5-1.2x1
    Geometry: Square (Q)
    Long Diagonal (LD): 6 mm
    Short Diagonal (SD): 4.5 mm
    Metal Strip Width (W): 1.2 mm
    Metal Thickness (T): 1 mm
    Total Thickness (TT): ≈ 1.5 mm
    Steel*: 4.2 kg/m²
    Front Open Area / max: ≈ 36% / 40%
    KD200 <br>Q8x6-1.2x1
    KD200
    Q8x6-1.2x1
    Geometry: Square (Q)
    Long Diagonal (LD): 8 mm
    Short Diagonal (SD): 6 mm
    Metal Strip Width (W): 1.2 mm
    Metal Thickness (T): 1 mm
    Total Thickness (TT): ≈ 2 mm
    Steel*: 3.2 kg/m²
    Frontal Void / max: ≈ 54% / 56%
    KD300 <br>Q10x7-1.5x1
    KD300
    Q10x7-1.5x1
    Geometry: Square (Q)
    Diagonal Long (DL): 10 mm
    Short Diagonal (DC): 7 mm
    Metal Strip Width (Lg): 1.5 mm
    Metal Thickness (Ep): 1 mm
    Total Thickness (EpT): ≈ 2.5 mm
    Steel*: 3.2 kg/m²
    Frontal Void / max: ≈ 57% / 66%
    KD400 <br> Q16x11-3x1
    KD400
    Q16x11-3x1
    Geometry: Square (Q)
    Long Diagonal (DL): 16 mm
    Short Diagonal (DC): 11 mm
    Metal Strip Width (Lg): 3 mm
    Metal Thickness (Ep): 1 mm
    Total Thickness (EpT): ≈ 4 mm
    Steel*: 4.3 kg/m²
    Frontal Void / Max: ≈ 46% / 59%
    RB15 <br>R10x5.8-1.5x1
    RB15
    R10x5.8-1.5x1
    Geometry: R (Diamond)
    Long Diagonal (LD): 10 mm
    Short Diagonal (SD): 5.8 mm
    Metal Strip Width (W): 1.5 mm
    Metal Thickness (T): 1 mm
    Total Thickness (TT): ≈ 2 mm
    Steel*: 4.1 kg/m²
    Frontal Void / max: ≈ 45% / 57%
    RB25 <br>R16x8-2x1
    RB25
    R16x8-2x1
    Geometry: R (Diamond)
    Long Diagonal (DL): 16 mm
    Short Diagonal (DC): 8 mm
    Metal Strip Width (Lg): 2 mm
    Metal Thickness (Ep): 1 mm
    Total Thickness (EpT): ≈ 3 mm
    Steel*: 4 kg/m²
    Front Open Area / max: ≈ 52% / 65%
    RB35 <br>R28x10-2x1.5
    RB35
    R28x10-2x1.5
    Geometry: R (Diamond)
    Long Diagonal (DL): 28 mm
    Short Diagonal (DC): 10 mm
    Metal web width (Lg): 2 mm
    Metal thickness (Ep): 1.5 mm
    Total thickness (EpT): ≈ 3.5 mm
    Steel*: 4.8 kg/m²
    Frontal void / max: ≈ 55% / 70%
    Compatible with active fire protection
    RB45 <br>R28x14-5x0.6
    RB45
    R28x14-5x0.6
    Geometry: R (Rhombus)
    Diagonal Long (DL): 28 mm
    Short Diagonal (DC): 14 mm
    Metal strip width (Lg): 5 mm
    Metal thickness (Ep): 0.6 mm
    Total thickness (EpT): ≈ 7 mm
    Steel*: 3.35 kg/m²
    Front gap / max: ≈ 33% / 50%
    RB55 <br>R43x13-2.5x1.5
    RB55
    R43x13-2.5x1.5
    Geometry: R (Rhombus)
    Long Diagonal (LD): 43 mm
    Short Diagonal (SD): 13 mm
    Metal Strip Width (SW): 2.5 mm
    Metal Thickness (MT): 1.5 mm
    Total Thickness (TT): ≈ 4 mm
    Steel*: 4.4 kg/m²
    Frontal Void / Max: ≈ 67% / 77%
    Compatible with active fire protection
    RB55 XL <br>R43x20-2.2x1.5
    RB55 XL
    R43x20-2.2x1.5
    Geometry: R (Diamond)
    Long Diagonal (DL): 43 mm
    Short Diagonal (DC): 20 mm
    Metal Flange Width (Lg): 2.2 mm
    Metal Thickness (Ep): 1.5 mm
    Total Thickness (EpT): ≈ 4.5 mm
    Steel*: 2.60 kg/m²
    Frontal Void Area / max: ≈ 79% / 84%
    Compatible with active fire protection
    RB65 <br>R62x23-8x0.6
    RB65
    R62x23-8x0.6
    Geometry: R (Diamond)
    Long Diagonal (LD): 62 mm
    Short Diagonal (SD): 23 mm
    Metal Strip Width (MSW): 8 mm
    Metal Thickness (MT): 0.6 mm
    Total Thickness (TT): ≈ 10 mm
    Steel*: 3.4 kg/m²
    Frontal Void / max: ≈ 36% / 60%
    RB75 <br> R85x35-11x1
    RB75
    R85x35-11x1
    Geometry: R (Diamond)
    Long Diagonal (DL): 85 mm
    Short Diagonal (DC): 35 mm
    Metal Strip Width (Lg): 11 mm
    Metal Thickness (Ep): 1 mm
    Total Thickness (EpT): ≈ 14 mm
    Steel*: 5.10 kg/m²
    Frontal Void / max: ≈ 48% / 70%
    Compatible with active fire protection
    3D Mesh Viewer
  • Colors

    Powder coated post-painted steel

    • White RAL 9003
    • White RAL 9010
    • White RAL 9016
    • Metallic Grey RAL 9006
    • Black RAL 9005
    • 180 RAL colors
    Post-laquered <br>White 9003
    Post-laquered White 9003
    Material: Steel
    Coating: Polyester powder post-painted 80 µm
    Color: White RAL 9003
    Gloss: 30 UB ±5
    Post-laquered <br>White 9003
    Post-laquered
    White 9003
    Material: Steel
    Coating: Polyester powder post-painted 80 µm
    Color: White RAL 9003
    Gloss: 30 UB ±5
    Postlacquered <br>White 9010
    Postlacquered
    White 9010
    Material: Steel
    Coating: 80 μm Polyester Powder Coated
    Color: White RAL 9010
    Gloss: 30 UB ±5
    Post-painted <br>White 9016
    Post-painted
    White 9016
    Material: Steel
    Coating: Post-painted polyester powder 80 µm
    Color: White RAL 9016
    Gloss: 30 UB ±5
    Post-painted <br>Gray 9006
    Post-painted
    Gray 9006
    Material: Steel
    Coating: Powder polyester post-painted 80 µm
    Color: Metallic Grey RAL 9006
    Gloss: 30 UB ±5
    Pre-painted <br>Black 9005
    Pre-painted
    Black 9005
    Material: Steel
    Finish: Powder-coated polyester 80 µm
    Color: Black RAL 9005
    Gloss: 30 UB ±5
    Post-painted <br>180 RAL colors
    Post-painted
    180 RAL colors
    Material: Steel
    Coating: Powder-coated polyester post-painted 80 µm
    Color: 180 RAL colors
    Gloss level: 30 to 80 UB ±5

Performance

  • Indoor air quality

    Class A+ for all products:

    • Unfilled
    • From the ALPHA PLUS range, with specific encapsulated insulation

    Class A for all products from the ALPHA PLUS range, with specific surfaced insulation

  • Sound absorption

    According to the standard EN ISO 11654

    • αw up to 1 (NRC = 1) with the ALPHA PLUS range

    Refer to the table in the Metal Acoustic Ceilings brochure.

  • Acoustic complement

    ALPHA PLUS offer: specific acoustic insulation covered with a veil or bagged in a PE film.
    Refer to the Acoustic page in the Product Catalog annexes for more details.

  • Corrosion resistance

    Ceiling indoors

    • Class B for standard steel frameworks according to EN 13964 standard
    • Corrosion resistance C1 according to EN 12944 for standard steel MESH panels (not covered by EN 13964)
    • Corrosion resistance 2a according to EN 13096 for aluminum MESH panels (not covered by EN 13964)
    • Suspensions and attachments to supports should be selected according to the desired class
    • Refer to the page Implementation in the Product Catalog Annexes for more details.

  • Cleanability

    By nature, our metal ceilings require minimal maintenance. However, various cleaning options are available. Please refer to the Maintenance page in the Product Catalog annexes for more details.

  • Reservations, integrations

    Customized factory cutting on request.

  • Opening

    Access to the plenum by vertical push then lateral translation to escape the hanging profile. Clearance from below by tilting it to one side.

  • Resistance to disinfection chemicals

    Our metal ceilings are resistant to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants (according to EN 12720 and ISO 11998 standards).

    Refer to the Maintenance page in the Product Catalog annexes for more details.

  • Active fire protection

    According to standard EN 12845

    • If sprinklers are installed above the open cell suspended panel, the total open flat surface area, including lighting fixtures, must not be less than 70% of the flat surface
    • In practice, a void percentage higher than 80% is commonly requested for panel elements

    Ceiling void percentage

    • Above 70%: RB35, RB55, RB55 XL, RB75
    • Above 80%: RB55 XL
  • Reaction to fire

    A2-s1, d0

General presentation of the system family

Family : Plafonds en métal déployé MESH

Ideal for office buildings, hospitals, airports, parking areas...

Aesthetic:

  • Wide range of meshes for different optical effects with natural or artificial light coming from the plenum
  • The metal appears more or less open depending on the installation and observation direction
  • Ideal solution for elegantly delimiting technical areas
  • Various finishes with hollow joint according to the systems

Acoustic:

  • Possibility of αw up to 1.00 (NRC = 1.00)

Practical:

  • Easy installation and opening
  • Robustness during handling
  • Allows active fire protection networks to operate through the ceiling

Sub-family : Plafond MESH autoportant pour circulations

MESH systems opening on concealed profiles

  • Adaptable to corridor width
  • Various finishes with open joints depending on the systems
  • Self-supporting from wall to wall avoiding suspended grids in crowded plenums
  • Wide plenum access
  • Natural plenum ventilation (if panel is not filled with mineral wool)