Translabac
Ideal for: high traffic areas
Product Benefits
- Opening: open position with the panel remaining in the plenum
- Acoustic: high correction, absorption coefficient αw up to 1
- Installation: adjustable closed hollow joint thanks to the system of two-part staggered edges
- Sealing: closed hollow joint to isolate equipment noise
Associated System:
Sliding panel system TRANSLABAC [PLAFOMETAL-CC-230]
Caracteristics & Performance
Acoustic absorption
- αw up to 0.85 (NRC = 0.85) with the ALPHA range
- αw up to 1 (NRC = 1.00) with the ALPHA PLUS range
Discover our video "Acoustic Metal Ceilings" in the Documentation/Videos section.
Acoustic filling
- Offer ALPHA: as standard, a black veil from PLAFOMETAL is thermally bonded to the back of perforated ceilings.
- Offer ALPHA PLUS: two filling options are available. A specific surface-insulated material for optimal performance or a specific bagged insulation to prevent fibers.
The acoustic performances of ceiling systems are guaranteed for defined, controlled, and fully delivered products by PLAFOMETAL.
Light Reflexion
- Up to 87%.
Fire reaction
According to standard EN 13501-1 :
- Euroclass A1 for non-perforated pre-coated products
- Euroclass A1 for pre-coated products from the ALPHA range
- Euroclass A2-s1, d0 for non-perforated powder-coated post-coated products
- Euroclass A2-s1, d0 for powder-coated post-coated products from the ALPHA range
- Euroclass A2-s1, d0 for products from the ALPHA PLUS range
Chemical resistance
Metal ceilings are resistant* to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants. However, we recommend certain disinfectants based on the type of ceiling:
- Sodium hypochlorite 2.5%: no visual changes on all ceilings
- Hydrogen peroxide 6%: only black post-lacquered ceilings show minor visual changes, no changes are observed on other ceilings
- Ethanol 70%: only white pre-lacquered, black post-lacquered, and wood finish ceilings show minor visual changes, no changes are observed on other ceilings
This also applies to all pre-lacquered/post-lacquered steel or aluminum products from the ALPHA, ALPHA PLUS, and DECIBEL ranges. *exposure according to EN 12720; disinfection and wet abrasion according to ISO 11998
Réglementations
Environment and health
- Our ceilings are 100% recyclable indefinitely.
- They are durable, easy to maintain, non-dust-generating, non-particle or vapor emitting, and are inert and odorless.
- They do not promote microbial growth and do not emit VOCs and formaldehydes.
- This product has a verified Environmental and Health Declaration Sheet (FDES), downloadable on the website www.inies.fr or in the section Documentations.
CE marking
- DoP No.: 0007-200
Indoor Air Quality
The products are classified:
- A+ for all non-perforated products
- A+ for all products from the ALPHA range
- A+ for all products from the ALPHA PLUS range, with specific encapsulated insulation
- A for all products from the ALPHA PLUS range, with specific surfaced insulation
Mise en oeuvre et entretien
Type of installation
- Installation in circulation areas
Implementation
- Implementation according to DTU 58.1
- Installation in circulation: Translabac angle to be fixed to the wall every 300 mm and Translabac hanging profile to be assembled by bolts (not provided) under the angle every 300mm.
Disassembling for access to the plenum
- Opening of the panel by vertical push, then translation and removal of the panel on the upper flanges of the edge profile. The panel then slides in the plenum above the panels left in place. Reinstallation in reverse manner.
Colors & Dimensions
Materials
- Galvanized steel thickness from 0.6 to 0.8 mm depending on width and length.
Colors and finishes
- Polyester pre-coated White 137 (~ RAL 9003).
- Polyester pre-coated Metallic Grey RAL 9006 on request.
- Polyester powder post-coating: 180 RAL shades on request.
Perforations on steel
- Non Perforated
- 11% Ø1.5 M
- 22% Ø1.5 M
- 10% Ø2.5 M
- 12% Ø2.5 U (perforated on 4 sides only)
- 16% Ø2.5 U (perforated on 4 sides only)
- 23% Ø2.5 M
- 20% 61x4 U (perforated on 4 sides only)
- 40% 61x4 U (perforated on 4 sides only)
- 18% Irregular ØIRR (max width 400 mm)
Module dimensions
- Widths 300, 400, and 600 mm. Others on request.
- Length on request (min. 800 - max. 2500 mm).
- Height 35 mm.
- Self-supporting up to 2500 mm for width 300 mm.
Product data sheet
Learn more on the Product data sheetCut outs and integrations
- Customized factory cutting on demand.