Square T15
Ideal for: shopping centers
Framed double-skin open cell on T15 grid
Product Benefits
Product Benefits
- Installation: quick installation on T-grid and easily removable
- Aesthetic: the T-grid blends with the panel
- Aesthetic: conceals the plenum in an indirect view while maintaining the impression of space and light
- Safety: significant open area for active fire protection systems
Associated System:
Framed double-skin open cell ceiling system on T grid SQUARE T15 [PLAFOMETAL-OC-110]
Caracteristics & Performance
Caracteristics & Performance
Acoustic filling
- Possibility to include insulation in the panel, held in place by its edge - please contact us for more information.
Fire reaction
According to the EN 13501-1 standard:
- Euroclass A1
Chemical resistance
Metal ceilings are resistant* to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants. However, we recommend certain disinfectants more particularly depending on the type of ceiling:
- Sodium hypochlorite 2.5%: no visual change on all ceilings
- Hydrogen peroxide 6%: only black post-painted ceilings show a minor visual change, no visual change is observed on other ceilings
- Ethanol 70%: only white pre-painted, black post-painted, and wood finish ceilings show a minor visual change, no visual change is observed on other ceilings
This also applies to all pre-painted/post-painted steel or aluminum products from the ALPHA, ALPHA PLUS, and DECIBEL ranges.*exposure according to EN 12720; disinfection and wet abrasion according to ISO 11998
Réglementations
Réglementations
Environment and health
- Our ceilings are 100% infinitely recyclable.
- They are durable, easy to maintain, non-dust-generating, non-particle or vapor-releasing, and are inert and odorless.
- They do not promote microbial growth and do not emit VOCs and formaldehydes.
CE marking
- DoP No.: 0007-200
Indoor Air Quality
- The products in the range are classified A+
Mise en oeuvre et entretien
Mise en oeuvre et entretien
Type of installation
- Grid installation
Implementation
- Implementation according to DTU 58.1
- Grid installation: hanger spacing 1200 mm with wall starting at 300 mm and carrier spacing 1200 mm.
Disassembling for access to the plenum
- By lifting one edge of the panel in the substructure.
Colors & Dimensions
Colors & Dimensions
Materials
- 0.4 mm thick aluminium.
Colors and finishes
- Standard White (RAL 9003) - Polyester prelacquered.
- Black (RAL 9005) - Polyester prelacquered.
- Metallic Grey (RAL 9006) - Polyester prelacquered on request.
Module dimensions
- 600 x 600 mm.
- Other dimensions available upon request.
Product data sheet
Learn more on the Product data sheetCut outs and integrations
- Recessed supports for spotlights, sprinklers, or other fixtures available on request.
Daily support
We offer our customers tailored support at every stage of a construction project. From the client's initial request to site supervision, Plafometal demonstrates its commitment to supporting its customers on a daily basis with tailored advice. Learn more
Documents