Fire-resistant swing-down ceiling on concealed profile with Orial SF panel
Common Horizontal Circulation (CHC) in high-rise buildingsPLAFOMETAL-CC-120 is a Fire-Resistant system adaptable to corridor dimensions. The ORIAL SF panels are self-supporting from wall to wall, avoiding the need for suspended structures in cluttered plenums with numerous distribution networks. They create an elegant reveal joint with the wall. Their robustness, combined with a large opening by swinging down on both sides, will facilitate maintenance phases throughout the building's lifespan.
Selection guide
- Acoustic comfort
- Fire resistant
The advantages of the system
- Aesthetic: concealed grid with off-set edge and shadow gap allowing for wall alignment variations for a perfectly straight finish
- Acoustic: high sound absorption, αw absorption coefficient up to 1 (NRC = 1)
- Opening: swing-down on both sides from below, ideal for crowded plenums
- Plenum ventilation: open shadow gap suitable for hospital environments
- Safety: Fire-Resistant ½ h and ¼ h to comply with regulations in common escape routes in high-rise buildings (IGH)
Description
- Swing-down opening ceiling made up of panels hooked on a concealed profile forming an open groove joint between the end of the panels and the wall
- Self-supporting steel panels with continuous edges and sharp angles
- The panels are equipped with notches at their ends allowing for their suspension on the grid and their swinging to one side or the other
- The concealed profile consists of a reprise trim to be fixed to the wall and a hanging profile to be shifted and fixed under the flange of the reprise trim according to the length of the panel between notches. It allows the open groove joint formed to absorb alignment deviations with the wall
- Acoustic enhancements available as an option
- Fire-Resistant Ceiling: refer to the installation guide Orial Fire-Resistant and always refer to the test reports and extensions available on request
Bulk cut
An A gap is required between the panel and the wall. Dimensions in mm.
Downloadable documents
Appearance
-
Perforations
Percentage of void, hole shape in mm, and hole arrangement
- On steel: Non-Perforated, 11% Ø1.5 M, 22% Ø1.5 M, 10% Ø2.5 M, 12% Ø2.5 U*, 16% Ø2.5 U*, 23% Ø2.5 M; Possibility to stop the perforation at the end of the panel
*Available only with 4-sided stopped perforation
Perforation range:
Refer to the paragraph Perforations of the "Metal Ceiling Finishes" page for more details.
11% Ø1.5 MVoid rate: 11%
Hole shape: Round Ø1.5
Hole arrangement: M
22% Ø1.5 MVoid rate: 22%
Hole shape: Round Ø1.5
Hole arrangement: M
10% Ø2.5 MVoid rate: 10%
Hole shape: Round Ø2.5
Hole arrangement: M
12% Ø2.5 UVoid rate: 12%
Hole shape: Round Ø2.5
Hole arrangement: U
16% Ø2.5 UVoid rate: 16%
Hole shape: Round Ø2.5
Hole layout: U
23% Ø2.5 MVoid rate: 23%
Hole shape: Round Ø2.5
Hole layout: M -
Colors
Precoated polyester steel
- White 137 (≈ RAL 9003)
Post-coated polyester powder steel
- White RAL 9003
- White RAL 9010
- White RAL 9016
- 180 RAL colors - on request
Refer to the paragraph Materials and coatings on the "Metal ceiling finishes" page for more details.
Pre-coated White 137Material: Steel
Coating: 25 µm Polyester precoating
Color: White 137 (≈ RAL 9003)
Gloss: 15 UB ±5
Pre-coated
White 137Material: Steel
Coating: 25 µm Polyester precoating
Color: White 137 (≈ RAL 9003)
Gloss: 15 UB ±5
Post-laquered
White 9003Material: Steel
Coating: Polyester powder post-painted 80 µm
Color: White RAL 9003
Gloss: 30 UB ±5
Postlacquered
White 9010Material: Steel
Coating: 80 μm Polyester Powder Coated
Color: White RAL 9010
Gloss: 30 UB ±5
Post-painted
White 9016Material: Steel
Coating: Post-painted polyester powder 80 µm
Color: White RAL 9016
Gloss: 30 UB ±5
Post-painted
180 RAL colorsMaterial: Steel
Coating: Powder-coated polyester post-painted 80 µm
Color: 180 RAL colors
Gloss level: 30 to 80 UB ±5
Performance
-
Light reflection
Up to 87%
-
Indoor air quality
Class A+ for all products:
- Non-perforated
- From the ALPHA range
- From the ALPHA PLUS range, with specific encapsulated insulation
Class A for all products from the ALPHA PLUS range, with specific surfaced insulation
-
Sound absorption
According to standard EN ISO 11654
- αw up to 0.80 (NRC = 0.80) with the ALPHA range
- αw up to 1 (NRC = 1) with the ALPHA PLUS range
Acoustic performances subject to the chosen perforation. Please refer to the table in the brochure Acoustic metal ceilings.
-
Acoustic complement
- ALPHA offer: Plafometal acoustic ceiling
- ALPHA PLUS offer: specific acoustic insulation surfaced with a veil or encapsulated in a PE film
Refer to the Acoustic page in the Product Catalog annexes for more details.
-
Fire Stability
The bays and SF edge profiles are specific and must always be implemented in accordance with the Minutes and extensions available on request. Also refer to the installation guide Orial Fire-Resistant.
-
Corrosion resistance
Indoor ceiling
- Class B according to standard EN 13964
- Suspensions and fixations to supports are to be selected according to the desired class
Refer to the page Implementation of the Product Catalog annexes for more details.
-
Cleanability
By nature, our metal ceilings require minimal maintenance. However, various types of cleaning are possible. Please refer to the Maintenance page in the Product Catalog Appendix for more details, including advanced high-pressure and dry steam cleaning.
-
Reservations, integrations
The ceiling must not support any other load than its own weight. Various equipment (lighting, ventilation, sound systems, signs, etc.) can be hung from the main or secondary structure of the building using hangers passing through the ceiling with minimal clearance. This secondary structure must then be checked for thermal performance, through testing or calculation according to the current standards referring to the CSTB test report.
-
Opening
Access to the plenum by vertical push of the panel followed by lateral translation to escape the hooking profile. The panel tilts and remains suspended on the opposite profile.
-
Resistance to disinfection chemicals
Our metal ceilings are resistant to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants (according to EN 12720 and ISO 11998 standards).Refer to the page Maintenance in the Product Catalog annexes for more details.
-
FDES Plafometal verified
FDES verified available on the INIES database (www.inies.fr) and in direct access on our website.
-
Reaction to fire
Euroclass A1 for products:
- Non-perforated precoated products
- Precoated products from the ALPHA range
- Non-perforated powder post-coated products
- Powder post-coated products from the ALPHA range
- From the ALPHA PLUS range
Euroclass A2-s1, d0 for products:
Technical properties
General presentation of the system family
Family : Plafonds autoportants pour les circulations
Ideal for office corridors, hospitals...
Acoustic:
- Acoustic comfort with an absorption index αw up to 1.00 (NRC = 1.00)
Aesthetic:
- Adaptable to corridor width
- Various finishes with hidden joints depending on the systems
- Ability to integrate equipment
- Custom-made recesses and light troughs
Practical:
- Self-supporting from wall to wall, avoiding suspended grids in crowded plenums
- Easy installation and access
- Wide access to the plenum
- Robustness during handling
Sub-family : Plafond ouvrant sur profils de rives cachés
Opening ceiling on concealed profiles
Swing-down systems with ORIAL PLAFOMETAL panels- Absorbing gaps in alignment with the wall joints - Swinging down on both sides from below for crowded plenums - Ventilation possible through the joint for hospital environments - Large dimension (XL) and Fire-resistant (SF) versions for High Rise Buildings (IGH)