Product Benefits

Product Benefits

  • Installation: offset grid to absorb wall alignment deviations
  • Aesthetic: monolithic ceiling appearance with striped installation
  • Acoustic: high correction, absorption coefficient αw up to 1
  • Plenum ventilation: suitable for hospital environments

Associated Systems:
- Hook-on panel on concealed profile system HORUS [PLAFOMETAL-CC-310]
- Hook-on panel on concealed carrier system HORUS [PLAFOMETAL-SC-210]

Caracteristics & Performance

Caracteristics & Performance

Acoustic absorption

  • αw up to 0.85 (NRC = 0.85) with the ALPHA range
  • αw up to 1 (NRC = 1.00) with the ALPHA PLUS range

Discover our video "Acoustic Metal Ceilings" in the Documentation/Videos section.

Acoustic filling

Offer ALPHA: as standard, a black veil PLAFOMETAL is thermally bonded to the back of perforated ceilings.
Offer ALPHA PLUS: two filling options are available. The specific faced insulation for optimal performance or the specific bagged insulation for ease of implementation.

The acoustic performance of ceiling systems is guaranteed for products defined, controlled, and fully delivered by PLAFOMETAL.

Light Reflexion

  • Up to 87%.

Fire reaction

According to standard EN 13501-1:

  • Euroclass A1 for non-perforated pre-painted products
  • Euroclass A1 for pre-painted products from the ALPHA range
  • Euroclass A2-s1, d0 for non-perforated powder-coated products
  • Euroclass A2-s1, d0 for powder-coated products from the ALPHA range
  • Euroclass A2-s1, d0 for products from the ALPHA PLUS range

Chemical resistance

Metal ceilings are resistant to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants. However, we recommend certain disinfectants based on the type of ceiling:

  • Sodium hypochlorite 2.5%: no visual change on all ceilings
  • Hydrogen peroxide 6%: only black post-painted ceilings show a minor visual change, no visual change is observed on other ceilings
  • Ethanol 70%: only white pre-painted, black post-painted, and wood finish ceilings show a minor visual change, no visual change is observed on other ceilings

This also applies to all pre-painted/post-painted steel or aluminum products in the ALPHA, ALPHA PLUS, and DECIBEL ranges.*exposure according to EN 12720; disinfection and wet abrasion according to ISO 11998

Réglementations

Réglementations

Environment and health

  • Our ceilings are 100% infinitely recyclable.
  • They are durable, easy to maintain, non-dust-generating, particle-free, and vapor-free, as well as inert and odorless.
  • They do not promote microbial growth and do not emit VOCs and formaldehydes.
  • This product has a verified EPD, which can be downloaded from the website www.inies.fr or in the section Documents.

CE marking

Indoor Air Quality

The products are classified:

  • A+ for all non-perforated products
  • A+ for all products in the ALPHA range
  • A+ for all products in the ALPHA PLUS range, with specific encapsulated insulation
  • A for all products in the ALPHA PLUS range, with specific surface insulation
Mise en oeuvre et entretien

Mise en oeuvre et entretien

Type of installation

  • Circulation laying
  • Tramme laying

Implementation

  • Implementation according to DTU 58.1
  • Installation in circulation: angle to be screwed to the wall every 300 mm
  • Tramming installation: hanger spacing every 1200 mm with wall starting at 300 mm and carrier spacing up to the self-supporting aspect of the panel. The edge finish can be accommodated with the profiles and the hollow joint used during circulation installation, provided that the length of the panels is compatible (full panels on the edge) with the room dimension.

Disassembling for access to the plenum

  • Disassembly of the panel by vertical push and lateral translation to escape the attachment profile (and the neighboring panel in the case of staggered installation). Clearance from below by tilting it to one side. Reinstallation in reverse order while respecting the alignment of one element with the other.
Colors & Dimensions

Colors & Dimensions

Materials

  • Galvanized steel thickness of 0.6 to 0.8 mm depending on width and length.

Colors and finishes

  • Polyester prelacquered White 137 (~RAL 9003).
  • Polyester prelacquered Metallic Grey RAL 9006 on request.
  • Polyester powder post-coating: 180 RAL colors available on request.

Perforations on steel

  • Non-Perforated
  • 11% Ø1.5 M
  • 22% Ø1.5 M
  • 10% Ø2.5 M
  • 12% Ø2.5 U (only with 4 sides stopped perforation)
  • 16% Ø2.5 U (only with 4 sides stopped perforation)
  • 23% Ø2.5 M
  • 20% 61x4 U (only with 4 sides stopped perforation)
  • 40% 61x4 U (only with 4 sides stopped perforation)
  • 18% Irregular ØIRR (max width 400 mm)

Module dimensions

  • Widths 300, 400, and 600 mm. Others available on request.
  • Length made to order (min 900 - max 2500 mm)
  • Height 35 or 50 mm.
  • Maximum self-supporting span: 3000 mm for a width of 300 mm and a height of 50 mm.

Cut outs and integrations

  • Customized factory cutting upon request.
Exemple

Daily support

We offer our customers tailored support at every stage of a construction project. From the client's initial request to site supervision, Plafometal demonstrates its commitment to supporting its customers on a daily basis with tailored advice.
Learn more