PM300 Interior
Ideal for: halls
Product Benefits
- Installation: Wide spacing and individually removable panels
- Acoustics: High correction, absorption coefficient αw up to 1
Associated System:
Clipped panel system on concealed carrier, PM300 Indoor [PLAFOMETAL-LC-210]
Caracteristics & Performance
Acoustic absorption
- αw up to 0.85 (NRC = 0.85) with the ALPHA range
- αw up to 1 (NRC = 1.00) with the ALPHA PLUS range
Découvrez notre video "Les plafonds métalliques acoustiques" dans la rubrique Documentations/Videos.
Acoustic filling
- ALPHA Offer: as standard, a black veil PLAFOMETAL is thermally bonded to the back of perforated ceilings.
- ALPHA PLUS Offer: two filling options are available. The specific surfaced insulant for optimal performance or the specific bagged insulant to prevent fibers.
The acoustic performance of the ceiling systems is guaranteed for defined, controlled, and fully supplied products by PLAFOMETAL.
Light Reflexion
- Up to 87%.
Fire reaction
According to standard EN 13501-1
Euroclass A1 for products:
- prelacquered non-perforated
- prelacquered from the ALPHA range
Euroclass A2-s1,d0 for products:
- powder-coated post-lacquered non-perforated
- powder-coated post-lacquered from the ALPHA range
- from the ALPHA PLUS range
Chemical resistance
Metal ceilings are resistant to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants. However, we recommend certain disinfectants depending on the type of ceiling:
- Sodium hypochlorite 2.5%: no visual change on all ceilings
- Hydrogen peroxide 6%: only black post-lacquered ceilings show a minor visual change, no visual change is observed on other ceilings
- Ethanol 70%: only white pre-lacquered, black post-lacquered, and wood finish ceilings show a minor visual change, no visual change is observed on other ceilings
This also applies to all pre-lacquered/post-lacquered steel or aluminum products in the ALPHA, ALPHA PLUS, and DECIBEL ranges. *exposure according to EN 12720; disinfection and wet abrasion according to ISO 11998
Réglementations
Environment and health
- Our ceilings are 100% infinitely recyclable.
- They are durable, easy to maintain, non-dust, particles, or vapor-generating, and are inert and odorless.
- They do not promote microbial growth and do not emit VOCs and formaldehydes.
- This product has a verified EPD, downloadable on the website www.inies.fr or in the section Documentation.
CE marking
- DoP No.: 0007-200
Indoor Air Quality
Class A+ for all products:
- unperforated
- from the ALPHA range
- from the ALPHA PLUS range, with specific bagged insulation
Class A for all products from the ALPHA PLUS range, with specific surfaced insulation.
Mise en oeuvre et entretien
Type of installation
- Interior clipped installation
Installation in damp environments: not compatible with chlorinated environments
Implementation
- Implementation clipped indoors according to DTU 58-1 and installation guide
- Installation is facilitated by large spacings, the elimination of the primary structure, and the use of a 'stepless' carrier. The use of I-HR carriers and 2.5mm thick stainless steel HR sliding hangers allows for the following maximum configurations:
- suspension spacing 1800mm and carrier spacing 2100mm
- suspension spacing 2400mm and carrier spacing 1200mm
Disassembling for access to the plenum
- Opening of the panels by using specific tools to insert to push the H clip and release the panel individually. For more details, refer to the installation guide or contact us.
Colors & Dimensions
Materials
- Galvanized steel thickness 0.6 mm
Colors and finishes
- White 137 (≈ RAL 9003) - Precoated polyester steel
- Metallic Gray RAL 9006 - Precoated polyester steel
- 180 RAL colors on request - Powder polyester post-coating
- Other colors on request depending on quantity - Precoated polyester aluminum
Perforations on steel
- Non Perforé = UNPERFORATED
- 11% Ø1.5 M = 11% Ø1.5 M
- 22% Ø1.5 M = 22% Ø1.5 M
- 10% Ø2.5 M = 10% Ø2.5 M
- 23% Ø2.5 M = 23% Ø2.5 M
Module dimensions
- Width 300 mm
- Length made to measure. Recommended dimension between 2000 and 4000 mm (minimum 900 - maximum 6000).
- Height 33 mm
- Carrier spacing 2100 maximum.
Product data sheet
Learn more on the Product data sheetCut outs and integrations
- On-site cutting