H8-E24
Ideal for: all types of premises.
Product Benefits
- Aesthetic: reinforced modular appearance
- Durability: resistance to repeated handling.
- Acoustic: high sound correction, absorption coefficient αw up to 1
Associated system:
Metal tiles system on T grid H0, H2, H8-E15, H8-E24 [PLAFOMETAL-SC-310]
Caracteristics & Performance
Acoustic absorption
- αw up to 0.80 (NRC = 0.80) with the ALPHA range
- αw up to 1 (NRC = 1.00) with the ALPHA PLUS range
Découvrez notre video "Les plafonds métalliques acoustiques" dans la rubrique Documentations/Videos.
Acoustic filling
- ALPHA offer: as standard, a black veil PLAFOMETAL is thermally bonded to the back of perforated ceilings.
- ALPHA PLUS offer: a specific insulated bag to be placed on the back of perforated ceilings.
The acoustic performances of ceiling systems are guaranteed for defined products, controlled and fully delivered by PLAFOMETAL.
Light Reflexion
- Up to 87%.
Fire reaction
According to standard EN 13501-1:
- Euroclass A1 for non-perforated pre-coated products
- Euroclass A1 for pre-coated products from the ALPHA range
- Euroclass A2-s1, d0 for non-perforated powder-coated post-coated products
- Euroclass A2-s1, d0 for powder-coated post-coated products from the ALPHA range
- Euroclass A2-s1, d0 for products from the ALPHA PLUS range
Chemical resistance
Metal ceilings are resistant* to 2.5% sodium hypochlorite, 6% hydrogen peroxide, or 70% ethanol disinfectants. However, we particularly recommend certain disinfectants based on the type of ceiling:
- Sodium hypochlorite 2.5%: no visual changes on all ceilings
- 6% hydrogen peroxide: only black post-lacquered ceilings show minor visual changes, no visual changes observed on other ceilings
- 70% ethanol: only white pre-lacquered, black post-lacquered, and wood-finish ceilings show minor visual changes, no visual changes observed on other ceilings
This applies to all pre-lacquered/post-lacquered steel or aluminum products in the ALPHA, ALPHA PLUS, and DECIBEL ranges. *exposure according to EN 12720; disinfection and wet abrasion according to ISO 11998
Réglementations
Environment and health
- Our ceilings are 100% infinitely recyclable.
- They are durable, easy to maintain, non-dust-generating, particle- or vapor-free, inert, and odorless.
- They do not promote microbial growth and do not emit VOCs and formaldehydes.
CE marking
- DoP No.: 0007-200
Indoor Air Quality
The products are classified as follows:
- A+ for all non-perforated products
- A+ for all products in the ALPHA range
- A+ for all products in the ALPHA PLUS range, with specific encapsulated insulation
Mise en oeuvre et entretien
Type of installation
- Lay-in installation
Implementation
- Implementation according to DTU 58.1
- Tramme installation: hanger every 1200 mm with wall starting at 300 mm and carrier every 1200 mm.
Disassembling for access to the plenum
- By simply lifting the panel in the grid.
- Access hatch available upon request, please contact us.
- Potential anti-lifting of the panel by adding CA113 brackets on the periphery.
Colors & Dimensions
Materials
- Galvanized steel thickness 0.5 mm.
- Aluminum thickness 0.6 mm on request.
Colors and finishes
- Polyester prelacquered White 137 (~ RAL 9003).
- Polyester prelacquered Metallic Grey RAL 9006 upon request.
- Polyester prelacquered Black RAL 9005 upon request.
- Polyester powder post-coating: 180 RAL colors upon request.
Perforations on steel
- Non Perforated
- 11% Ø1.5 M
- 22% Ø1.5 M
- 10% Ø2.5 M
- 12% Ø2.5 U (only with 4-sided stopped perforation)
- 16% Ø2.5 U (only with 4-sided stopped perforation)
- 23% Ø2.5 M
- 46% 5.5x5.5 U (only in 600*600 mm)
- 11% 61x4 U (not stocked)
Module dimensions
- 600x600, 600x1200, 675x675, 625x625 mm.
- Other dimensions available upon request
Product data sheet
Learn more on the Product data sheetCut outs and integrations
- Customized factory cutting on demand.