H8-E15
Ideal for: all types of premises.
Product Benefits
- Aesthetics: reinforced modular appearance
- Strength: resistance during repeated handling.
- Acoustics: high correction, absorption coefficient αw up to 1
Associated System:
Metal tiles on T grid system H0, H2, H8-E15, H8-E24 [PLAFOMETAL-SC-310]
Caracteristics & Performance
Acoustic absorption
- αw up to 0.80 (NRC = 0.80) with the ALPHA range
- αw up to 1 (NRC = 1.00) with the ALPHA PLUS range
Discover our video "Acoustic Metal Ceilings" in the Documentation/Videos section.
Acoustic filling
- ALPHA offer: as standard, a black veil PLAFOMETAL is thermally bonded on the back of perforated ceilings.
- ALPHA PLUS offer: a specific encapsulated insulant to be applied on the back of perforated ceilings.
The acoustic performances of the ceiling systems are guaranteed for defined, controlled, and fully delivered products by PLAFOMETAL.
Light Reflexion
- Up to 87%.
Fire reaction
According to the EN 13501-1 standard:
- Euroclass A1 for non-perforated pre-coated products
- Euroclass A1 for pre-coated products from the ALPHA range
- Euroclass A2-s1, d0 for non-perforated powder-coated post-coated products
- Euroclass A2-s1, d0 for powder-coated post-coated products from the ALPHA range
- Euroclass A2-s1, d0 for products from the ALPHA PLUS range
Chemical resistance
Metal ceilings are resistant to sodium hypochlorite 2.5%, hydrogen peroxide 6%, or ethanol 70% disinfectants. However, we recommend specific disinfectants depending on the type of ceiling:
- Sodium hypochlorite 2.5%: no visual changes on all ceilings
- Hydrogen peroxide 6%: only black post-lacquered ceilings show minor visual changes, no visual changes on other ceilings
- Ethanol 70%: only white pre-lacquered, black post-lacquered, and wood finish ceilings show minor visual changes, no visual changes on other ceilings
This also applies to all pre-lacquered/post-lacquered steel or aluminum products from the ALPHA, ALPHA PLUS, and DECIBEL ranges.*exposure according to EN 12720; disinfection and wet abrasion according to ISO 11998
Réglementations
Environment and health
- Our ceilings are 100% infinitely recyclable.
- They are durable, easy to maintain, non-dust, particle, or vapor-generating, and are inert and odorless.
- They do not promote microbial growth and do not emit VOCs and formaldehydes.
CE marking
- DoP No.: 0007-200
Indoor Air Quality
The products are classified as:
- A+ for all non-perforated products
- A+ for all products from the ALPHA range
- A+ for all products from the ALPHA PLUS range, with specific encapsulated insulation
Mise en oeuvre et entretien
Type of installation
- Grid installation
Implementation
- Implementation according to DTU 58.1
- Grid installation: hangers every 1200 mm with wall starting point at 300 mm and carriers every 1200 mm.
Disassembling for access to the plenum
- By simply lifting the panel within the grid.
- Access door available, please contact us.
- Potential anti-lifting of the panel by adding CA113 brackets at the perimeter.
Colors & Dimensions
Materials
- 0.5mm thick Galvanized steel.
- 0.6mm thick Aluminum available on request.
Colors and finishes
- Polyester pre-painted White 137 (~ RAL 9003).
- Polyester pre-painted Metallic Grey RAL 9006 on request.
- Polyester pre-painted Black RAL 9005 on request.
- Polyester powder post-painting: 180 RAL shades on request.
Perforations on steel
- Non-Perforated
- 11% Ø1.5 M
- 22% Ø1.5 M
- 10% Ø2.5 M
- 12% Ø2.5 U (only on 4 sides stopped perforation)
- 16% Ø2.5 U (only on 4 sides stopped perforation)
- 23% Ø2.5 M
- 46% 5.5x5.5 U (only in 600*600 mm)
- 11% 61x4 U (not stocked)
Module dimensions
- 600x600, 600x1200, 675x675, 625x625 mm.
- Other dimensions available upon request
Product data sheet
Learn more on the Product data sheetCut outs and integrations
- Customized factory cutting available on request.